王烨, 鲍成柯, 付银安, 王乐李. 圆锥形顶太阳能蓄热水箱锥顶结构及运行参数优化[J]. 农业工程学报, 2017, 33(22): 255-261. DOI: 10.11975/j.issn.1002-6819.2017.22.033
    引用本文: 王烨, 鲍成柯, 付银安, 王乐李. 圆锥形顶太阳能蓄热水箱锥顶结构及运行参数优化[J]. 农业工程学报, 2017, 33(22): 255-261. DOI: 10.11975/j.issn.1002-6819.2017.22.033
    Wang Ye, Bao Chengke, Fu Yin'an, Wang Leli. Study of structure optimization of solar hot water storage tank with conical top[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2017, 33(22): 255-261. DOI: 10.11975/j.issn.1002-6819.2017.22.033
    Citation: Wang Ye, Bao Chengke, Fu Yin'an, Wang Leli. Study of structure optimization of solar hot water storage tank with conical top[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2017, 33(22): 255-261. DOI: 10.11975/j.issn.1002-6819.2017.22.033

    圆锥形顶太阳能蓄热水箱锥顶结构及运行参数优化

    Study of structure optimization of solar hot water storage tank with conical top

    • 摘要: 为获得顶部为圆锥形结构的太阳能蓄热水箱最优锥顶结构及运行参数,对水箱在有内置隔板情况下的10种锥顶结构进行了数值设计,结果表明:在给定流动参数条件下,锥顶角在173.1°~118.1°间变化对水箱内热分层影响效果相当,高温热水区域范围略有增大;对于锥顶高度为0.09 m、锥顶角为159.6°的最佳结构水箱,水箱出口附近高温热水区域范围随冷水入口流速增大逐渐缩小、随热水入口温度提高而增大,但提高热水入口温度对于高温热水区域范围的增大程度在较高冷水入口流速时要小于较低冷水入口流速时的情况;在其他流体参数不变的情况下,冷热水出口温差随冷水入口流速增大呈上升趋势,但当冷水入口流速增大到一定值时其对增大冷热水出口温差的贡献趋于平缓;在冷水入口流速较小时提高热水入口温度对于增大冷热水出口温差的贡献要略大于冷水入口流速较大时的情况。热水入口温度为333 K、冷水入口温度为303 K、热水入口流速为0.05 m/s、冷水入口流速为0.9 m/s组合而成的工况以及热水入口温度为343 K、冷水入口温度为303 K、热水入口流速为0.05 m/s、冷水入口流速为0.9 m/s组合而成的工况适合于"小流量大温差"的热用户运行模式;热水入口温度为333 K、冷水入口温度为303 K、热水入口流速为0.05 m/s、冷水入口流速为0.1 m/s组合而成的工况以及热水入口温度为343 K、冷水入口温度为303 K、热水入口流速为0.05 m/s、冷水入口流速为0.1 m/s组合而成的工况适合于热用户对热水供应量需求较大的情况。

       

      Abstract: Abstract: Solar hot water storage tank is one of the key thermal storage equipment of the solar energy system and it has significant effect on the reliability of thermal energy supply. For the solar hot water storage tank, its optimal structure and reasonable fluid parameters are very important for improving the solar energy system efficiency. Published references indicate that the hot water storage tank with conical top has better performance than the hot water storage tank with plane top. But there is no study about the relationships among the cone vertex angles, fluid parameters and the thermal stratification effect for the hot water storage tank with conical top. This paper mainly aims to obtain the optimal structure of the solar hot water storage tank with conical top and the operating parameters. The standard k-ε model was adopted to analyze the influence of cone vertex angle and operating parameters on the thermal stratification of the hot water storage tank with conical top. The results show that the studied cone vertex angles have a little effect on thermal stratification and the hot water region slightly expands with the decreasing of cone vertex angle. In terms of the optimal water storage tank with the conical top height of 0.09 m and cone vertex angle of 159.6°, the hot water region is reduced with the increasing of cold water inlet velocity and the decreasing of hot water inlet temperature. However, higher hot water inlet temperature has less effect on the hot water region on condition of higher cold water inlet velocity than that of lower cold water inlet velocity. Thus, in practical engineering operation, to improve hot water inlet temperature under lower cold water inlet velocity can obtain better thermal stratification effect. For given fluid parameters, the difference between the hot water outlet temperature and cold water outlet temperature increases with the increasing of cold water inlet velocity. Increasing hot water inlet temperature under lower cold water inlet velocity makes a slightly larger contribution to improving the difference between the hot water outlet temperature and the cold water outlet temperature. To improve hot water inlet temperature from 333 to 343 K has no effect on the cold water outlet temperature in this study. One case with hot water inlet temperature of 333 K, cold water inlet temperature of 303 K, hot water inlet velocity of 0.05 m/s and cold water inlet velocity of 0.9 m/s and the other case with hot water inlet temperature of 343 K, cold water inlet temperature of 303 K, hot water inlet velocity of 0.05 m/s and cold water inlet velocity of 0.9 m/s are suitable to the running mode of "low flow flux and high temperature difference". One case with hot water inlet temperature of 333 K, cold water inlet temperature of 303 K, hot water inlet velocity of 0.05 m/s and cold water inlet velocity of 0.1 m/s and the other case with hot water inlet temperature of 343 K, cold water inlet temperature of 303 K, hot water inlet velocity of 0.05 m/s and cold water inlet velocity of 0.1 m/s are suitable for the users with large demand for hot water supply. In order to obtain high efficiency of solar energy system in practical engineering, many factors, such as types of solar collectors, local weather conditions, specific requirements of thermal users and operation modes must be considered simultaneously.

       

    /

    返回文章