    Citation: XIANG Bintao, GUO Hua, WANG Junlin, et al. Stability performance and parameter analysis of section-steel arched solar greenhouses[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2024, 40(13): 196-204. DOI: 10.11975/j.issn.1002-6819.202312091

    型钢拱架日光温室结构稳定性能及参数分析

    Stability performance and parameter analysis of section-steel arched solar greenhouses

    • 摘要: 型钢拱架日光温室结构的主要受力构件长细比大,暴雪等极端灾害天气下易引发结构失稳灾变。针对此问题,该研究利用弹塑性力学理论和非线性有限单元法,建立型钢拱架日光温室结构精细化有限元模型,开展雪荷载下日光温室稳定性能分析;通过对型钢截面类型(平椭圆形截面、箱形截面和几字形截面)、温室跨度(8、10和12 m)、雪荷载分布形态(分布厚度非均匀和分布区域不对称)等参数下日光温室失稳全过程分析,分别确定日光温室稳定承载力,揭示雪荷载分布对日光温室稳定承载力的量化影响;结合日光温室的荷载系数-位移全过程曲线和不同加载时刻点的变形图、应力图、轴力图与弯矩图,从直观现象和内在本质两个层面深入探明日光温室的静力失稳机理。分析结果表明:在保证不发生平面外整体失稳的前提下,当型钢截面面积和翼缘宽度相同时,相较于箱形截面型钢、几字形截面型钢,采用平椭圆形截面型钢拱架的日光温室稳定承载力分别提高了19.2%和44.2%;跨度对日光温室稳定承载力的影响较大,与8 m跨度相比,10、12 m跨度的日光温室的荷载系数分别下降了27.1%和57.9%;相较于均匀分布雪荷载,在非均匀分布雪荷载下日光温室的稳定承载力最大下降63.8%;相较于不设置拉杆和撑杆的情况,单独设置拉杆的日光温室稳定承载力最大可提高9.0%,单独设置撑杆的日光温室稳定承载力最大可提高66.8%。该研究得出的结果和给出的建议可为型钢拱架日光温室结构抗雪设计、稳定性研究和防灾分析提供技术指导和理论参考。

       

      Abstract: Solar greenhouses have been widely used in the vast western and northern regions of China, due mainly to the convenient construction and installation, low economic cost, and outstanding environmental adaptability. The slender steel can be the load-bearing components of the section-steel arched solar greenhouse to resist external loads, such as wind and snow. There are the prominent instability and disaster that caused by insufficient stiffness of solar greenhouse under extreme weather conditions, such as snowstorms. In this study, the nonlinear stability analysis was conducted on the commonly-used section-steel arched solar greenhouse in Hebei using elastic-plastic mechanics and nonlinear finite element (FE). A refined FE model was established for the section-steel arched solar greenhouse. The greenhouse arch roof and the vertical sections on both sides were simulated using the Beam188 element in the element library of the universal FE analysis program ANSYS. The linear elements were used to fit the circular arc segments. Diagonal tension bars, vertical brace struts, and longitudinal tie bars were all simulated using Link10 element. The bottom of the vertical sections on both sides of the arch was assumed to be consolidated with the foundation. The steel was made of Q235, with an elastic modulus of 206 GPa, a Poisson's ratio of 0.3, and a density of 7 850 kg/m3. Geometric and material nonlinearity was considered to simulate the constitutive relationship of steel using an ideal elastic-plastic model, followed by von Mises yield criterion and bilinear kinematic hardening model BKIN. The stability performance and parameter analysis of solar greenhouse structure were carried out under snow loads. The stability capacity of solar greenhouse was determined under different parameters, such as steel-section type (flat elliptical, hollow rectangular and hat-shaped cross-section), greenhouse span (8, 10, and 12 m), and snow load distribution pattern (non-uniform distribution thickness and asymmetric distribution area). There was the quantitative influence of snow load distribution on the stability capacity of solar greenhouses. The load factor-displacement curves were combined with the deformation, stress, axial, and bending moment at different points of loading time. The static instability of solar greenhouses was explored from two aspects: intuitive phenomena and intrinsic essence. The conclusions were obtained as follows: The stability capacity of the steel component with a flat elliptical section in the solar greenhouse was increased by 21.0% and 44.2%, respectively, compared with the box and hat-shaped section. There was no out of plane instability in the same cross-sectional area and flange width of the steel component. The stability capacity of solar greenhouse was rapidly reduced with the increase of span. The stability capacity of solar greenhouse under non-uniform distribution of snow loads was reduced by the maximum of 63.8%, compared with the uniform. The maximum stability capacity of a solar greenhouse increased by 9.0% and 66.8% with only tension bars and brace struts, respectively. The findings can provide the technical guidance and theoretical reference for the anti-snow loads, stability and disaster prevention in the section-steel arch solar greenhouses.

       

    /