    Zhang Zijun, Chen Jiahong, Huang Yafeng, Guo Xiaofei, Luo Zhongyue, Ling Yinghui. Detection and evaluation of microclimatic ambient air in goat shed in Jianghuai region in summer[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2013, 29(18): 200-209. DOI: 10.3969/j.issn.1002-6819.2013.18.024
    Citation: Zhang Zijun, Chen Jiahong, Huang Yafeng, Guo Xiaofei, Luo Zhongyue, Ling Yinghui. Detection and evaluation of microclimatic ambient air in goat shed in Jianghuai region in summer[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2013, 29(18): 200-209. DOI: 10.3969/j.issn.1002-6819.2013.18.024

    江淮地区夏季羊舍小气候环境检测及评价

    Detection and evaluation of microclimatic ambient air in goat shed in Jianghuai region in summer

    • 摘要: 为了探明中国南方羊舍环境条件和存在的问题,在江淮地区选择南方最常见的双坡式漏缝地板有窗封闭羊舍,连续2a对其夏季最热月(7月)的空气环境指标进行了检测和分析,结果表明:1)该类羊舍最热月空气日平均温度、相对湿度、气流速度、光照强度、噪音与氨气质量浓度和二氧化碳体积分数分别为30.5℃、70.2%、0.16 m/s、99.45 lx、49.82 dB、1.98 mg/m3、0.060%,以上指标中,除日平均温度超标外,其他各项指标均符合环境卫生学标准;2)不同采样点(离地0.3、1、1.7 m)测定结果显示各参数(空气温度、相对湿度、氨气和二氧化碳浓度)夏季空间分布特征差异不显著;3)随着外界环境的变化,舍内空气温度和相对湿度有明显的日变化规律,而一月内的变化比较稳定,阴雨天降温幅度较大(6.9℃),试验期昼夜平均温差为2.3℃,舍内外平均温差为1.8℃;4)舍内氨气和二氧化碳浓度日、月变化幅度均较小;5)氨气浓度与空气温度和相对湿度之间存在显著的正相关性(r=0.8702,P<0.05)。综合评价认为,双坡式漏缝地板有窗封闭羊舍小气候环境基本符合环境卫生学标准和山羊的生物学特性要求,适宜在江淮地区推广应用,但在炎热的夏季需要采取一定的降温措施。该研究可为一般羊舍小气候环境的测定及参数评价提供一定的参考。

       

      Abstract: Abstract: In order to ascertain the environmental condition of goat shed and its existing problems in South China, this study had been conducted for two years to detect and analyze the air environmental indicators in double-sloped airtight goat houses with windows and slatted floor, which was the most commonly seen type of goat house in Southern China, in summer in Jianghuai Region. The results showed that: ① daily mean temperature, relative humidity, airflow velocity, illuminance, noise and concentration of nitrogen and carbon dioxide in such goat houses in the hottest month in summer were 30.5℃、70.2%、0.16 m/s、99.45 lx、49.82 dB、1.98 mg/m3、0.060% respectively. All indicators met the required standards of environmental hygiene except for the daily mean temperature. ②Measurement in different sampling points of goat houses showed that characteristics of space distribution of each above-mentioned parameters were not very apparent. ③As outside environment changed, daily mean temperatures and relative humidity in the sampling points also changed apparently. The shift was relatively steady in January, while temperatures in rainy days dropped fairly significantly (6.9℃). Average temperature difference between days and nights during the trial period was 2.3℃. Average indoor and outdoor temperature difference in the goat houses was 1.8℃. ④ Daily and monthly concentration of nitrogen and carbon dioxide in the sampling sites shifted slightly. ⑤There was a significant negative correlation between temperature and relative humidity of the air in the sampling sites (r=-0.9818, P<0.01), while a significant positive correlation was detected between the concentration of nitrogen and the temperature and relative humidity of the air (r=0.8702, P<0.05). It is recognized based on the comprehensive evaluation that microclimatic environment of double-sloped airtight goat house with windows and slatted floor is basically in accordance with biological characteristics of environmental hygiene and goats. Thus, this type of goat house is suitable to be promoted and applied in Jianghuai Region, and it is only necessary to take certain measures to lower the temperature in the houses in hot summer weather.

       

    /