地—气热交换塑料大棚中热量平衡的研究

    Studies on the Heat Balance of Polyvinyl Chloride (PVC) Greenhouse with an Earth-Air heat Exchanger

    • 摘要: 本文通过严格一致的对比观测条件,研究和分析了地-气热交换系统的热性能及其对塑料大棚中气候环境、作物生长和产量的影响;在理论分析和实际观测的基础上计算了塑料大棚中热量平衡;从经济效益和节约能源的角度对该设施的可行性和实用性作了客观的评价。实验结果表明:地-气热交换系统可使塑料大棚在夜间升温2.0—4.4℃,在白天降温2.5—6.5℃;使作物的开花期和收获期提前大约10天,而使晚秋作物(黄瓜)延后生长约15天;草莓和黄瓜的产量分别增加了51%和45%;地-气热交换塑料大棚与对照塑料大棚的热量收支有明显的不同,在夜间对照大棚热量损失较大;从经济效益和节能效果看,该设施在华北地区和黄淮流域具有一定的可行性和实用性。

       

      Abstract: The main objectives of this paper are to study and analyse the heat characteristics of an earth-air heat exchange system (EHES) and its effects both on the climatic environment of PVC-greenhouse and the crop yields. Based on the observed data, the heat balance of the two greenhouses has been calculated.In order to verify the feasibi lity and the practicality of the EHES, the economic benefit and the energy saving have also objectively been evaluated.The experimental results are as follow:1.The rate of the heat release from the EHES and the heat storage into the EHES were 8700kcal/ hr.and 18471kcal / hr.respectively.The ratio of the both rates was 0.47.2. The air temperature observed and calculated inside greenhouse A, which attached with the EHES, had risen 2.0-4.4℃ , and 2.6-9. 6℃ (u= 1.5m/sec) respectively at night, as compared with greenhouse B, which was without the EHES .On the contrary, the air temperature observed and calculated inside greenhouse A was 2.5-6.5℃ , and 6.2-15.1 ℃ lower than that of greenhouse B during the daytime (u = 2.0m / sec.) .3. The verage soil temperature observed and calculated at 0-50cm depth inside greenhouse A was 2.3℃ , and 1.8℃ higher than that of greenhouse B due to the influence of the EHES.4. The heat balance of greenhouse A was much different from that of greenhouse B not only at the daytime, but also at night.The energy shortage of greenhouse B was far greater than that of greenhouse A during the whole night.5.The yields of strawberry and cucumber planted in greenhouse A increased by 51% and 45% over that of greenhouse B respectively.6.It seemed very feasible and practical to apply this installation from the point of view of the economic benefit and the enery saving.

       

    /

    返回文章
    返回