缀铝箔保温幕保温性能测试分析

    Experimental Analysis on the Insulation Performance of Aluminized Thermal Screens

    • 摘要: 通过测试对比,分析了缀铝箔保温幕对温室内温度变化的影响,对保温幕的节能效果进行了计算分析,发现由于采用开间间拉幕方式密封不严,系统的节能率在温室加温期间仅有20%左右,与国外同类系统相比,存在很大差异。最后对如何改进拉幕系统,提高保温幕的节能效果提出了具体措施,对温室的温度管理模式提出了建议。

       

      Abstract: The influence on the temperature fluctuation inside greenhouses and energy saving of aluminized screens were analyzed and calculated on the basis of measurement. The results indicated that the truss to truss installation of screen driving systems leads to 20% of energy saving, which is much lower than that of good foreign systems. At the end of this article, some suggestions were put forward to improve energy saving performance of screen systems and temperature management mode was proposed to change a little bit in accordance with the practice.

       

    /