华南型单栋塑料温室风荷载模拟试验研究

    Simulation Test of Wind Load Characteristics of South China Type Single-Span Plastic Greenhouse

    • 摘要: 该文对华南型单栋塑料温室的风荷载特性进行了风洞模拟试验研究,测量了在16种不同风向角下温室风荷载体型系数大小和分布规律,详细讨论了屋檐、天窗等外伸部位对温室风荷载分布的影响。试验结果表明,华南型温室中的屋檐和天窗使其风荷载分布与建筑结构荷载规范的规定有较大区别,屋檐、屋脊、两端和天窗均为风荷载集中的部位。抗风设计应主要考虑与温室侧墙垂直的风荷载,在温室端部应设置支撑或提高屋檐和屋脊结构强度

       

      Abstract: A simulation test on the wind load characteristics of South China type single span plastic greenhouse was conducted. The distribution regularities of the structural shape coefficient of wind load on the roof and wall of greenhouse are introduced. The influence of wind load on the column and roof windows are discussed. The wind tunnel test results show that the distribution of wind load on the greenhouse are different from one of the architecture standard because of the columns and roof windows. The wind loads are concentrated on the columns and roof windows. The wind loads when β=90° are the basis of wind load design. The brace may be used in the ends of the greenhouse or the strength of frame may be increased.

       

    /