    圆台型太阳能热泵设计及其制热性能

    Design and heating performance of solar-assisted heat pump with truncated-cone-type evaporator

    • 摘要: 该文对圆台型太阳能热泵的结构做了设计说明,建立了各部件的数学模型,并计算出各部件配置。样机采用圆台型为太阳能热泵的集热/蒸发器,测试条件在昆明太阳辐射较弱的12月,在平均吸收太阳辐射为7.2 MJ时,系统平均制热性能系数COP为3.1,当系统吸收了15.6 MJ的太阳能时,系统的COP可达3.8,说明该样机制热性能较高,能满足用户生活用水的要求。

       

      Abstract: Configuration of the solar-assisted heat pump with an innovative truncated-cone-type evaporator was designed. Mathematical models for parts of every system were set up. The results showed that when the average absorbance of solar radiation of a solar-assisted heat pump with a truncated-cone-type evaporator was 7.2 MJ, the coefficient of performance(COP) of the system was 3.1 under poor solar radiation in December in Kunming, China. When the system absorbed 15.6 MJ of solar radiation, the system’s COP could reach 3.8. The results indicate that the solar-assisted heat pump with a truncated-cone-type evaporator has high heating performance and can meet the demands of water supply.

       

    /