张金珠, 王钦, 王振华, 徐鑫. 基于太阳能光伏光热技术的灌溉水增温系统试验[J]. 农业工程学报, 2021, 37(16): 72-79. DOI: 10.11975/j.issn.1002-6819.2021.16.010
    引用本文: 张金珠, 王钦, 王振华, 徐鑫. 基于太阳能光伏光热技术的灌溉水增温系统试验[J]. 农业工程学报, 2021, 37(16): 72-79. DOI: 10.11975/j.issn.1002-6819.2021.16.010
    Zhang Jinzhu, Wang Qin, Wang Zhenhua, Xu Xin. Experimental study on irrigation water warming system based on solar photovoltaic/thermal technology[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2021, 37(16): 72-79. DOI: 10.11975/j.issn.1002-6819.2021.16.010
    Citation: Zhang Jinzhu, Wang Qin, Wang Zhenhua, Xu Xin. Experimental study on irrigation water warming system based on solar photovoltaic/thermal technology[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 2021, 37(16): 72-79. DOI: 10.11975/j.issn.1002-6819.2021.16.010

    基于太阳能光伏光热技术的灌溉水增温系统试验

    Experimental study on irrigation water warming system based on solar photovoltaic/thermal technology

    • 摘要: 为减弱低温灌溉水对中国西北地区作物带来的不利影响,减少农业灌溉中的能源消耗,该研究设计了一种基于太阳能光伏光热技术灌溉水增温系统。通过搭建测试平台,对该系统进行不同流量下的性能测试研究,分析初始水温和辐照度对系统性能的影响。结果显示,出水口水温和升温幅度与流量呈负相关关系,固定工况下,出水口水温及升温幅度最高可达20.9和12.5 ℃,光电、光热效率与流量呈正相关关系,最大分别为0.094和0.310,实际能量效率则先增后减,最大达到0.484。初始水温越低,光伏光热集热器内换热越剧烈,升温幅度越高,能量指标越大,但流量增加使得不同初始水温灌溉水升温幅度趋于一致,出水口水温变幅增大。辐照度越高,出水口水温及升温幅度越大,但流量增大会削弱辐照度对其产生的提升效果,光电、光热效率均与辐照度呈负相关关系,在流量小于0.06 kg/(s·m2)时,实际能量效率与辐照度呈负相关关系,在流量大于0.07 kg/(s·m2)时则相反。研究表明该系统总体性能良好,为不同工况下的流量选择提供了参考依据。

       

      Abstract: Abstract: The purpose of this study was to present a dedicated experimental investigation on the performance of a novel irrigation water warming system using solar photovoltaic/thermal technology. A combination was designed, including a flat-plate PV/T collector, the insulation barrels, the submerged pump, the frequency changer, the tungsten halogen lamp, and the system pipe. The cold irrigation water absorbed the heat through the flat-plate PV/T collector, where the temperature of photovoltaic modules was reduced for higher photoelectric efficiency. The experimental platform for the irrigation water warming system was built, where a series of tests were conducted under different working conditions, including the liquid mass flow rates 0.01-0.08 kg/(s·m2), initial water temperatures (5,7.5, 10 ℃), and the radiations (320, 465, and 650 W/m2). All 72 working conditions in total were conducted in the test, where the door and windows were closed in the room, and the temperature was controlled at 20 ℃ by the air conditioner. An analysis was made on the irrigation water temperature, the extent of temperature, photoelectric efficiency, solar thermal efficiency, and practical energy performance of the system. The results show that the outlet water temperature and the increasing extent of temperature reached 20.9 and 12.5 ℃, both of which were negatively correlated with the mass flow rate, particularly under the fixed condition, where the initial water temperature was 7.5 ℃, and the radiation was 465 W/m2. Nevertheless, the solar electric and thermal efficiency were positively correlated with the mass flow rate. The practical energy efficiency increased first and then decreased with the mass flow rate up rating, reaching a maximum of 0.484, where the inflection point was 0.03 kg/(s·m2). Besides, the irrigation water temperature, the extent of temperature, and energy performance of the system were compared under the middle radiation and different initial working condition of water temperatures. The heat transfer was much more intense, as the initial water temperature decreased, thereby causing the higher increasing extent of temperature. The initial water temperature was still an important factor to determine the water temperature of the outlet, indicating a positive correlation, and the maximum water temperature of the outlet of 22.6 ℃. Additionally, the solar electric efficiency, solar thermal efficiency, and practical energy efficiency were negatively correlated with the initial water temperature. Furthermore, irrigation water temperature and extent of temperature were relatively larger, when the system was under the higher solar radiation, but the increase of mass flow rate weaken the influence on the two indexes. The outlet water temperatures were maintained at about 10 ℃ when the system operated at 0.08 kg/(s·m2) with 7.5 ℃ irrigation water under different solar radiation. The solar electric efficiency and solar thermal efficiency were also negatively correlated with the solar radiation, where the maximum values were 0.096 and 0.417, respectively. Moreover, the practical energy efficiency was negatively correlated with the solar radiation, when the mass flow rate was less than 0.06 kg/(s·m2). It was just the opposite trend, when the mass flow rate was greater than 0.07 kg/(s·m2). In terms of application prospect, the initial investment of irrigation water heating system was higher using solar photovoltaic technology, compared with the traditional greenhouse photovoltaic roof, but the whole life cycle cost was smaller, and the LCC was reduced by 17.6%, considering the comprehensive energy benefits. The system was still in the stage of research and experimental study. The actual installation area can be further addressed, according to the actual outdoor irradiance, irrigation amount, irrigation time, required irrigation water temperature.

       

    /

    返回文章
    返回