Abstract
Aerobic composting has been one of the most effective ways to dispose the livestock and poultry manure. Resource utilization can also be realized to decompose the organic matter in the large-scale piles. Microorganisms can then be transformed into the stable humus. Among them, bottom aeration can serve as a large-scale aerobic composting project. There is a high demand for the effective design of a bottom aeration system for the high efficiency of oxygen transfer. The local anaerobic formation can be inhibited to improve the composting environment. This study aims to simulate and test the flow field in the pipeline of the large-scale aerobic composting bottom aeration system. The basic oxygen consumption was required for four sizes of piles (48, 90, 180, and 270 m3), in order to obtain the parameters of fans and pipelines; The actual pipelines existed in a certain pile. According to the air and hole distribution of pipelines, the flow field model was reconstructed in the bottom aeration system using Solid Works (USA) software; Different schemes of the pipeline (three air distribution patterns and two hole-layout) were simulated using Fluent fluid simulation software. The distribution of flow velocity was explored in the pipeline and at the vents. According to the case simulation of the 100 m3 reactor in the factory, there was no significant difference between the flow velocity after simulation and the actual measured value. The results indicated that: 1) Different sizes of piles were required the different air volumes and pressures. In the 48 m3 reactor, the length, width, and height of the aeration system were 8, 4, and 1.5 m, respectively. The inner diameter of the pipeline was 95 mm, and the ventilation air volume and partial pressure were 254.6 m3/h and 897.5 Pa, respectively. In the 90 m3 reactor, the length, width, and height of the aeration system were 10, 6, and 1.5 m, respectively, the inner diameter of the pipeline was 123 mm, and the ventilation air volume and partial pressure were 424.3 m3/h and 563.8 Pa, respectively. In the 180 m3 reactor, the length, width, and height of the aeration system were 20, 6, and 1.5 m, respectively, the inner diameter of the pipeline was 151 mm, and the ventilation air volume and partial pressure were 636.9 m3/h and 416.1 Pa, respectively. In the 270 m3 reactor, the length, width, and height of the aeration system were 30, 6, and 1.5 m, respectively, the inner diameter of the pipeline was 213 mm, and the ventilation air volume and partial pressure were 1 273 m3/h and 280 Pa, respectively. The fan models in the 48, 90, 180, and 270 m3 reactors were selected as 2 A (1.1 kW), 1.5 A (0.37 kW), 2 A (0.37 kW), and 2 A (1.1 kW), respectively. 2) A systematic investigation was made to explore the effects of pile sizes, gas distribution, and hole distribution on the gas flow and uniformity distribution at the vent holes in the pipeline. In the small-scale reactors (48 and 90 m3), there was little effect of air distribution on the uniformity of the flow velocity distribution in the ducts and at the ventilation holes, whereas the uniformity was improved with progressively denser holes, compared with uniform holes. In the large-scale reactors (180 and 270 m3), the uniformity of the reactors was improved by the multiple rows of pipelines, where the kinetic energy loss was reduced by 10 %. In addition to the size of the reactor, the particle size of the reactor, the shape of the holes, the angle of the pipes, and the number of holes were subsequently considered as variable parameters in the design of the ventilation system. 3) According to the case simulation of the 100 m3 reactor in the factory, there was no difference from the flow velocity after simulation with the actual measured value. The findings can provide a theoretical basis and data support for the subsequent engineering construction. But there are many influencing factors under the actual working conditions, such as intake air speed, wind pressure, and pipeline processing, leading to the ventilation effect. Field experiments are needed for further analysis on the ventilation.