Yin Yongguang, Yin Jinjie, Sun Dongsheng. Model Test Study on Temperature Distribution in Pulsed Electric Field Treatment Chamber[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 1998, 14(1): 51-54.
    Citation: Yin Yongguang, Yin Jinjie, Sun Dongsheng. Model Test Study on Temperature Distribution in Pulsed Electric Field Treatment Chamber[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 1998, 14(1): 51-54.

    Model Test Study on Temperature Distribution in Pulsed Electric Field Treatment Chamber

    • The temperature distribution in a Pulsed Electric Field(PEF) treatment chamber was measured by a model test method. Under static condition,the temperature distribution from orifice to electrodes is on exponential decay. Under continuous flow condition,the temperature distribution is not uniform. The temperature of the points located in upper vessel near the orifice and on the insulation are high.
    • loading

    Catalog

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return