Effects of temperature and bulk density on measurement precision of soil moisture sensor based on frequency domain reflectometry
-
-
Abstract
Abstract: Moisture content of soil is helpful for water-saving irrigation. Soil moisture sensors using frequency domain reflectometry (FDR) are more and more popular in market. Soil temperature is a major factor affecting moisture measurement precision. So it has been widely considered in developing FDR soil moisture sensor. However, volume density, which is also a major factor influencing measurement precision of soil moisture, has been considered hardly. To investigate the comprehensive influence of temperature and volume density on moisture content by FDR moisture sensor, Lou soil in Yangling region, Shaanxi Province, were used as samples , and DSW-T2 soil temperature and moisture sensor (current output type) using FDR technology, was used as instrument to study the influence of moisture content at seven levels (3.82%, 7.58%, 9.29%, 11.65%, 14.87%, 18.61%and 21.43% in wet basis), volume density at five levels (0.91 g/cm3, 1.00 g/cm3, 1.09 g/cm3, 1.21 g/cm3 and 1.30 g/cm3) over temperature range from 2.5℃ to 50℃ at 2.5℃ interval on output current. DM6801 digital temperature sensor was used to measure soil temperature and to detect precision of DSW-T2 on temperature measurement. A comprehensive mathematical model between output current, moisture content, volume density and temperature was established. Newton iteration method was applied to predict moisture content under laboratory conditions. The model's feasibility in predicting moisture content from 3.82%~21.43% and volume density from 0.91g/cm3-1.30g/cm3 at 2.5-50℃ was verified. The results indicated that the output current of DSW-T2 increased with increasing moisture content, volume density and temperature over the investigated range of each factor. The absolute error between calculated temperature from obtained output current of DSW-T2 and measured one using DM6801 was within -3.8%-10.7%. The absolute error between calculated moisture content by output current of DSW-T2 and measured one by oven-drying method was -2.2℃-2.4℃. A quadratic model with three-degree of freedom could be used to describe the relationship between output current of DSW-T2 and moisture content, volume density and temperature of soil. At 0.05 significant level, soil moisture content, temperature and volume density had significant effect on the model. The absolute error between calculated output current and measured one was between -1.167-1.216mA. The absolute error between calculated moisture content and actual one was within -2.638%-2.812% when the output current, temperature and volume density were given. By comparing the moisture content obtained by DSW-T2 soil temperature and moisture sensor with out volume density information and calculated one by the regressed three-degree model considering the volume density, it showed that considering volume density is helpful to improve moisture measurement precision. The study offers useful information on developing a comprehensive measurement model for FDR soil moisture sensor with temperature and volume density compensation functions.
-
-